[1] Miller RW (1989) Flow Measurement Engineering Handbook. second ed. McGraw Hill Publishing Company, New York, pp. 7.1–7.8.
[2] Singh SN, Seshadri V, Singh RK, Gawhade R (2006) Effect of upstream flow disturbance on the performance characteristics of a V-Cone flowmeter, Flow Meas. Instrum. 17(5): 291-297
[3] Singh Rajesh Kumar, Singh SN, Seshadri V(2010) CFD prediction of the effects of the upstream elbow fittings on the performance of cone flowmeters, Flow Meas. Instrum. 21: 88–97
[4] Borkar Kishor, Venugopal A, Prabhu SV (2013) Study on the design and performance of a bi-directional cone flowmeter, Flow Meas. Instrum. 34: 151-159
[5] Zheng Xuebo, Sun Xiaodong, Bai Bofeng (2018) Flow rate measurement of low GVF gas-liquid two-phase flow with a V-Cone meter. Exp. Therm. Fluid Sci. 91: 175-183
[6] فدایی مهدی، عاملی فروغ، هاشم آبادی سیدحسن (1398) مطالعه تجربی و شبیه سازی CFDاندازهگیری جریان دوفازی با استفاده از دبی سنج روزنهای. پژوهش نفت. شماره 108
[7] Nasiruddin Sheikh, Singh SN, Veeravalli SV, Hegde S (2019) Shape optimization of the cone body for the improved performance of the V-cone flowmeter: A numerical study. Flow Meas. Instrum. 66: 111-118
[8] Nasiruddin Sheikh, Singh SN, Veeravalli SV, Hegde S (2020) Effect of Reynolds number and boundary layer thickness on the performance of V-cone flowmeter using CFD. Flow Meas. Instrum. 73: 101728
[9] Nasiruddin Sheikh, Singh SN, Veeravalli SV, Hegde S (2020) Flow characteristics of back supported V-cone flowmeter (wafer cone). Flow Meas. Instrum. 73: 101750
[10] Zhao Fan, Li Shanshan, Zheng Xuebo, He Denghui, Bai Bofeng (2021) A modified model for wet gas flowrate measurement considering entrainment downstream of a cone meter. Flow Meas. Instrum. 77: 101839
[11] Li Shanshan, Bai Bofeng (2022) Two-phase mass flow coefficient of the cone flow meter. 3rd International Symposium on Thermal-Fluid Dynamics (Online). 28-30
[12] He Deng-Hui, Bai Bo-Feng (2014) Two-phase mass flow coefficient of V-Cone throttle device. ETF Science. 57: 77-85
[13] ISO 5167-5, Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 5: Cone meters, First ed., 2016.
[14] جزیرئیان حسام، جعفرکاظمی فرزاد، ربیعیفر حمیدرضا (1400) ارزیابی عددی عملکرد فلومتر مخروطی در دو حالت تقارن محوری و سه بعدی. پنجمین همایش ملی اندازه گیری جریان سیالات در صنایع نفت، گاز، پالایش، پتروشیمی و آب، تهران
[15] جزیرئیان حسام، جعفرکاظمی فرزاد، ربیعیفر حمیدرضا (1400) مطالعه عددی ساختارهای طولی و عرضی جریان در فلومتر مخروطی. دهمین کنفرانس ملی کاربرد CFD در صنایع شیمیایی و نفت، کرمانشاه
[16] Jaroslav Š (2016) Contribution to investigation of turbulent mean-flow velocity profile in pipe of circular cross-section. AIP Conference Proceedings 1768, 020010
[17] Zagarola MV, Smits AJ (1998) Mean-flow scaling of turbulent pipe flow. J. Fluid Mech. 373: 33 – 79