<ArticleTitle>Technical and Economic Feasibility Study of the Use of Phase Change Materials (PCMs) in the Combination of Compression Refrigeration and Free Cooling Systems, Case Stusy: A Residential Building in Kerman</ArticleTitle>
<VernacularTitle>Technical and Economic Feasibility Study of the Use of Phase Change Materials (PCMs) in the Combination of Compression Refrigeration and Free Cooling Systems, Case Stusy: A Residential Building in Kerman</VernacularTitle>
			<FirstPage>51</FirstPage>
			<LastPage>66</LastPage>
			<ELocationID EIdType="pii">2423</ELocationID>
			
<ELocationID EIdType="doi">10.22044/jsfm.2022.10454.3324</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>S.M.H.</FirstName>
					<LastName>Mohammadi</LastName>
<Affiliation>Department of Energy, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2021</Year>
					<Month>01</Month>
					<Day>16</Day>
				</PubDate>
			</History>
		<Abstract>Thermal Energy Storage (TES) is a high potential technology for different thermal energy applications. TES technology can be an appropriate approach to fill in the gap between electrical energy supply and demand. One efficient and modern method to store thermal energy is the use of phase-change materials (PCMs). The aim of this research is to study the feasibility of the use of PCM materials in the combination of free cooling and compression refrigeration systems. The combined system should be analyzed from energy and exergy viewpoints, in order to evaluate the amount of saved energy and the system performance upgrade. The medium temperature PCM coupled with the free cooling system, can be charged during the cool night time. During the hot day time, discharging this PCM would lower the temperature of the air entering the condenser and consequently; lower the HVAC system energy consumption. On the other hand, PCM discharge happens during the peak-hours in which the electrical energy price is high. Therefore, using PCM would reduce the building energy bills. Technical and economic results show that the proposed combined system would reduce the total electrical energy consumption up to 4.85%, energy consumption in peak-hours up to 14.76% and the electrical energy bill up to 6.71%.</Abstract>
			<OtherAbstract Language="FA">Thermal Energy Storage (TES) is a high potential technology for different thermal energy applications. TES technology can be an appropriate approach to fill in the gap between electrical energy supply and demand. One efficient and modern method to store thermal energy is the use of phase-change materials (PCMs). The aim of this research is to study the feasibility of the use of PCM materials in the combination of free cooling and compression refrigeration systems. The combined system should be analyzed from energy and exergy viewpoints, in order to evaluate the amount of saved energy and the system performance upgrade. The medium temperature PCM coupled with the free cooling system, can be charged during the cool night time. During the hot day time, discharging this PCM would lower the temperature of the air entering the condenser and consequently; lower the HVAC system energy consumption. On the other hand, PCM discharge happens during the peak-hours in which the electrical energy price is high. Therefore, using PCM would reduce the building energy bills. Technical and economic results show that the proposed combined system would reduce the total electrical energy consumption up to 4.85%, energy consumption in peak-hours up to 14.76% and the electrical energy bill up to 6.71%.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Compression refrigeration system</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Free cooling system</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Phase Change Material</Param>